Please use this identifier to cite or link to this item: http://hdl.handle.net/11455/2055
DC FieldValueLanguage
dc.contributor邱顯俊zh_TW
dc.contributor陳永銓zh_TW
dc.contributor.advisor曾柏昌zh_TW
dc.contributor.advisorPai-Chung Tsengen_US
dc.contributor.author吳培輝zh_TW
dc.contributor.authorWu, Peir-Hueien_US
dc.contributor.other中興大學zh_TW
dc.date2010zh_TW
dc.date.accessioned2014-06-05T11:42:26Z-
dc.date.available2014-06-05T11:42:26Z-
dc.identifierU0005-2001200911163700zh_TW
dc.identifier.citation[1] 我的E政府網站: http://www.moi.gov.tw/outline/9.htm [2] 原著:中井多喜雄,陳博文譯。防災消防設備的技術,千華,民85年。 [3] 經濟部中央標準局,CNS 3658 火災分類,民79年 [4] UL260英文標準,吳培輝譯。UL260消防用乾管閥及一齊開 (UL260 Dry Pipe and Deluge Valves for Fire Protection Services),民96年。 [5] Approval Standard for Deluge Systems and Preaction Systems, Class Number1011and 1012 November 1973(一齊放水系統及預動作系統認證標準) [6] Approval Standard for Dry Pipe Valves, Class Number 1021 November 1973(乾管閥認證標準) [7] NFPA 13 Standard For Installation of Sprinkler System , 2002.(撒水系統安裝之標準) [8] NFPA 25 Standard for the Inspection, Testing and Maintenance of Water-based Fire Protection Systems, 2003 (水系消防系統之檢查、測試與維護之標準)。 [9] 財團法人消防安全中心基金會網站http://www.cfs.org.tw/ [10] 財團法人消防安全中心基金會印製,一齊開放閥認可基準(九十一年六月十四日 內授消字0910088833號函頒) [11] Viking公司網站http://www.jerman.com/fire-sprinkler.com/deluge.htm [12] Reliable 公司網站: http://www.reliablesprinkler.com/pdfs/products/ [13] 彰得公司網站:http://www.cdfp.com.tw/ [14] 日本消防檢定協會,一齊開放閥之檢定細則,1999。 [15] 馮俊益著,水系統法令解說,財團法人中華民國消防技術顧問基金會,民八十五年,117頁。 [16] 消防法,各類場所消防安全設備設置標準。 [17] 簡賢文著,水系統消防安全設備,鼎茂圖書出版公司,民八十五年,5-2頁。 [18] 經濟部中央標準局,消防用一齊開放閥,民86年。 [19] 劉祥輝編著,消防工程實務,中國電機技術出版社,民七十三年,81頁。 [20] 劉哲雄編著,消防設備,現代人出版社,民七十一年,32頁。 [21] 邱昱孜,”專業運動器材系統化設計概論-以橢圓交叉訓練機為例”,中興大學機械系碩士論文,2007。 [22] 經濟部中央標準局,水泵出水量檢驗法,民93年。 [23] 經濟部中央標準局,閥之檢驗總則,民93年。zh_TW
dc.identifier.urihttp://hdl.handle.net/11455/2055-
dc.description.abstract隨著人口密集及經濟成長,火災對社會造成的傷害與日俱增;希望藉由本論文之研究,能改善現行一齊開放閥之諸多缺失,令使用功能獲得改善,以增強消防系統功能,及為延長耐用年限。而與一齊開放閥相搭檔的自動警報逆止閥,亦可藉由本文之論述,力行改善。 本論文利用3D繪圖軟體Soild Works來進行結構設計,並且在CAE的部份,我們對一齊開放閥的關鍵零組件如閥體、閥蓋進行模擬特性分析。 應用COSMOSXpress分析軟體,經由設定重要零組件的材質、負載、及拘束面,做有限元素分析,透過軟體產生實體網格,以分析變形量、應力分佈等。一般材料會在高於降伏強度或遠較極限抗拉強度大之荷重下,發生破壞,分析結果以了解是否可能因變形造成洩漏、破壞問題,並利用參考之安全係數,事先對原設計加以修正,以節省試作原型的投資浪費。zh_TW
dc.description.abstractIn following to the population highly concentration and economic growth, the fire accidents usually result in human life harmfulness and property losses, we expect that through this study, enable us to improve the defective of current deluge valve, make an improvement on the service performance, to enhance the fire protection system, and prolong the service duration. An accompany of the automatic alarm check valves is to be improved through this study. In this thesis, we adopted the 3D CAD Solidworks to conduct the structure design, further more, in the portion of CAE (Computer Aid Engineering), we focus on the critical parts, such as the valve body and cover , conduct the simulative characteristics analysis. then we employed the software of COSMOSXpress for analysis through the critical parts for material, load and restrictive face. By construction grids, COSMOSXpress can analysis the deformation, stress distribution etc. A normal material shall failure beyond its load of yield strength or ultimate tensile strength. As the results of analysis for reference, we properly know whether the deformation will cause leakage, fracture, by setting the relative safety factor. As a result, we can modify the original design in advance, and reduce the investment cost waste for prototype fabrication.en_US
dc.description.tableofcontents誌謝 摘要……………………………………………………………………………….. i Abstract…………………………………………………………………………… ii 目次………………………………………………………………………………. iii 圖目次…………………………………………………………………………….. v 表目次…………………………………………………………………………….. vi 第一章 緒論……………………………………………………………………… 1 1.1研究動機與背景………………………………………………………… 1 1.1.1美國保險協會(業)實驗室的由來(Found of UL Inc) …………….. 4 1.1.2工廠聯合保險商協會的由來(Found of FM,Factory Mutual)…... 5 1.1.3美國國家消防協會(Formed of NFPA)……………………………. 6 1.1.4內政部消防署的沿革(Found of National Fire Administration)…... 7 1.1.5財團法人消防安全中心基金會的設置(Found of CFS)………….. 7 1.2研究目的………………………………………………………………… 7 1.3研究流程………………………………………………………………… 8 1.4文獻回顧………………………………………………………………… 9 第二章 一齊開放閥應用理論…………………………………………………… 12 2.1一齊開放閥種類沿革與功能簡介……………………………………… 12 2.2一齊開放閥的應用理論基礎…………………………………………… 13 2.3改良型一齊開放閥的基本構造………………………………………… 16 2.4改良型一齊開放閥的設計及功能需求………………………………… 18 2.4.1基本功能設計……………………………………………………... 18 2.4.1.1一齊開放閥之最高使用壓力範圍…………………..…… 18 2.4.1.2一齊開放閥之耐壓試驗…………………..……………… 18 2.4.2螺栓強度設計……………………………………………………... 19 2.4.3襯墊及隔膜片設計………………………………………………... 20 第三章 模擬測試及分析方法…………………………………………………… 21 3.1一齊開放閥實體繪製…………………………………………………… 21 3.2一齊開放閥的模擬測試………………………………………………… 22 3.2.1閥蓋模擬結果…………………………...………………………… 23 3.2.2閥體模擬結果...…………………………………………………… 26 3.3改良之設計成品…....…………………………………………………… 28 第四章 實品功能測試及結果…………………………………………………… 30 4.1耐壓試驗………………………………………………………………… 30 4.2洩漏試驗………………………………………………………………… 31 4.3動作試驗………………………………………………………………… 32 4.4最大流量放水試驗……………………………………………………… 34 4.5壓力損失值計算………………………………………………………… 34 4.6橡墊之材質試驗………………………………………………………… 35 第五章 結論與未來展望………………………………………………………… 37 5.1研究結論………………………………………………………………… 37 5.2未來展望………………………………………………………………… 39 參考文獻………………………………………………………………………….. 41 附錄一 BX一齊開放閥構圖及動作概況……………………………………….. 44 附錄二 一齊開放閥之安裝、使用、維修保養注意事項.…………………….... 46 附錄三 一齊開放閥之供用場所……………………………………………….... 49 附錄四 一齊開放閥之設計規範……………………………………………….... 50 附錄五 一齊開放閥之品質管制工程表及製造流程圖…………………..…….. 52 附錄六 一齊開放閥動作與放水量之量測用四角堰………………………..….. 54 附錄七 ASTM A307 規格表………………………………………………….….. 58zh_TW
dc.language.isoen_USzh_TW
dc.publisher機械工程學系所zh_TW
dc.relation.urihttp://www.airitilibrary.com/Publication/alDetailedMesh1?DocID=U0005-2001200911163700en_US
dc.subjectDeluge Valveen_US
dc.subject一齊開放閥zh_TW
dc.subjectControl Valveen_US
dc.subjectFire Equipmenten_US
dc.subject控制閥zh_TW
dc.subject消防器材zh_TW
dc.title消 防 用 控 制 閥 改 良 設 計-以 一 齊 開 放 閥 為 例zh_TW
dc.titleAn Improvement Design of Control Valve for Fire - Protection Service-A Case Study of Deluge Valveen_US
dc.typeThesis and Dissertationzh_TW
Appears in Collections:機械工程學系所
文件中的檔案:

取得全文請前往華藝線上圖書館



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.