Please use this identifier to cite or link to this item: http://hdl.handle.net/11455/69374
標題: Cosmetic Hydrogen Peroxide Detection Using Nano Bismuth Species Deposited Built-in Three-in-One Screen-Printed Silver Electrode
作者: Chiu, M.H.
Kumar, A.S.
Sornambikai, S.
Chen, P.Y.
Shih, Y.
Zen, J.M.
期刊/報告no:: International Journal of Electrochemical Science, Volume 6, Issue 7, Page(s) 2352-2365.
摘要: A built-in three-in-one screen-printed electrode assembly containing nano bismuth species deposited silver as working, pre-oxidized silver as reference and unmodified silver as counter electrodes (designated as SPAgE-Bi(nano)), has been developed for simple electrochemical sensing of H(2)O(2) in pH 7 phosphate buffer solution. The working electrode showed similar to 250 mV reduction in over-potential and a two-fold increased peak current values for electrocatalytic reduction of H(2)O(2) over the respective unmodified silver working electrode (i.e. SPAgE) following a diffusion-controlled electron-transfer mechanism. 50 nm sized Bi particles on SPAgE surface was seen in SEM picture of the working electrode. Linear range of H(2)O(2) detection from 100 mu M to 5 mM, a sensitivity of 0.627 mu A/mM and detection limit (S/N = 3) of 56.59 mu M were obtained. Finally, SPAgE-Bi(nano) sensor assembly was utilized for cosmetic H(2)O(2) determination, where obtained values and labeled values were in good agreement with recovery in the range of 94.75-101.03 %.
URI: http://hdl.handle.net/11455/69374
ISSN: 1452-3981
Appears in Collections:期刊論文

文件中的檔案:

取得全文請前往華藝線上圖書館



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.