Please use this identifier to cite or link to this item: http://hdl.handle.net/11455/96123
標題: 鋼筋摩擦焊接續接工法品質之研究
The Quality of Reinforcing Bar Coupler with Friction Welding
作者: Hsiao-Chen Hsu
許筱晨
關鍵字: 摩擦焊接續接器
力學性質
變異性分析
Reinforcing bar coupler with friction welding
Analysis of mechanical properties
Variability
引用: 1.Somayaji, S., Civil engineering materials, Prentice Hall, Upper Siddle River, New Jersey (2001). 2.Mindess, S., Young, J.F., and Darwin D., Concrete, Prentice Hall (2003). 3.湯兆緯、陳冠宏、張朝順編譯,「土木材料」,高立圖書公司,民國91 年9 月出版。 4.Metha, P.K. and Monteiro, P.J.M., Concrete; Microstructure, Properties and Materials, 3rd Edition, McGraw-Hill, New York(2006). 5.王智勇,王仲宇,現行鋼筋續接器試驗方法的比較 6.陳正誠、沈進發、許峻榮,「鋼筋續接器在構材中性能檢測之研究」,內政部建築研究所專題計畫研究成果報告,計畫編號:MOIS 850011,1996。 7.陳正誠、沈進發,「鋼筋續接器之施工規範與使用準則研究」,內政部建築研究所專題計畫研究成果報告,計畫編號:MOIS 850026,1997。 8.內政部營建署暨內政部建築研究所,「鋼筋續接器續接施工規範及解說(草案)」,民國88 年。 9.中國土木水利工程學會,「混凝土工程設計規範與解說401-86a」,台北,科技圖書股份有限公司,民國89 年。 10.陳正誠,「鋼筋續接器之設計及施工規範修訂之研究」,建築物耐震,建築研究計畫聯合研討會,內政部建築研究所主辦,民國93 年11 月。 11.中國土木水利工程學會,「混凝土工程設計規範與解說」,台北,科技圖書股份有限公司,2011。 12.陳正誠,鋼筋工程技術發展,科技圖書股份有限公司,台北,2000。 13.內政部營建署,「混凝土結構設計規範」,台北,2011。 14.中華民國結構工程學會,「鋼筋續接器續接規範」工作小組工作報告(CSSE 96-01),中華民國96 年1 月。 15.行政院公共工程委員會公共工程施工綱要規範第03210 章鋼筋http://pcces.archnowledge.com/csi/Default.aspx?FunID=Fun_9 16.內政部建築研究所鋼筋續接器續接施工規範及解說http://www.abri.gov.tw/utcPageBox/CHIMAIN.aspx?ddsPageID=CHIMPA&DBID=212 17.Ling, J.H., Rahman A.B.A., Ibrahim I.S., Hamid, Z.A., 'Behaviour of grouted pipe splice under incremental tensile load',Constr Build Mater, Vol. 33, pp 90–98, 2012. 18.Sayadi, A.A., Rahman, A.B.A., Jumaat, M.Z.B, Alengaram, U.J., Ahmad, S. 'The relationship between interlockingmechanism and bond strength in elastic and inelastic segment of splice sleeve', Constr Build Mater, Vol. 55, pp 227–237,2014. 19.Sayadi, A.A., Rahman, A.B.A., Ahmad, S., Bahmani, M., Shahryari, L., 'Effective of elastic and inelastic zone on behavior ofglass fiber reinforced polymer splice sleeve', Constr Build Mater, Vol. 80, pp 38–47, 2015. 20.Ling, J.H., Rahman A.B.A., Ibrahim I.S., Hamid, Z.A., 'Tensile capacity of grouted splice sleeves', Constr Build Mater, Vol.111, pp 285–296, 2016. 21.ACI Committee 439, Mechanical connections of reinforcing bars, Farmington Hills: American Concrete Institute, 1999. 22.Haber, Z.B., Saiidi, M.S., Sanders, D.H., 'Behavior and simplified modeling of mechanical reinforcing bar splices', ACIStruct J, Vol. 112, No. 2, pp 179–188, 2015. 23.日本土木學會,「鐵筋繼手指針」,Concrete Library 49,Dec.,1981。 24.日本建築學會,「Recommendation for Detailing and Placing of Concrete Reinforcement」,1986。 25.American Society for Testing and Materials (ASTM), A 1034/A 1034M – 05b: Standard Test Methods for Testing Mechanical Splices for Steel Reinforcing Bars, 2005 26.王淑真,「高強度鋼筋機械式續接與錨定性能評估基準之研修」,國立雲林科技大學營建工程系碩士班碩士論文,2009年。 27.李宏仁、王淑真,「論新世代鋼筋續接器性能評定方法高強度鋼筋機械式續接與錨定性能評估基準之研修」,混凝土科技,第三卷,第二期,頁58~67,2009 年。 28.張國忠,「混凝土結構鋼筋續接器研究與應用探討」,朝陽科技大學營建工程系碩士論文,2015 年。 29.ACI 352R., Recommendations for design of beam-column connections in monolithic reinforced concrete structures (reported by Joint ACI-ASCE committee 352), American concrete Institute. U.S.A. 2002. 30.蔡竺真,「T 頭錨定鋼筋拉拔試驗研究」,國立台北科技大學土木與防災研究所碩士論文,2013 年。 31.羅俊雄,詹穎雯,徐雨義,鄭橙標,汪向榮,許丁友,「Headed Bar 應用於混凝土梁柱接頭之力學行為評估」,國家地震工程研究中心報告,報告編號NCREE-00-023,台北,2000。 32.李啟瑞,「螺紋節鋼筋之續接器續接及T 型錨定在結構構件上次應用」,碩士論文,國立台灣科技大學營建工程系,台北,2004。 33.張勝欽,「鋼筋機械式錨定工法之回顧與檢討」,碩士論文,國立雲林科技大學營建工程系,雲林,2006。 34.Li, L., Jiang, Z., 'Flexural Behavior and Strut-and-tie Model of Joints with headed bar detailsConnecting Precast Members',Perspectives in Science, Vol. 7, pp. 253—260, 2016. 35.Kim, S., 'Lap Splices in Tension Between Headed Reinforcing Bars And Hooked Reinforcing Bars of Reinforced Concrete Beam', IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE), Vol. 13, Issue 3 Ver. I, pp 71-75, 2016. 36.Thompson, M.K., Ledesma, A., Jirsa, J.O., Breen, J.E., 'Lap Splices Anchored by Headed Bars', ACI Structural Journal, Vol.103, No. 2, pp. 271-279, 2006. 37.Lee, Y.T., Kim, S.H., Chea, S.H., Bahn, B.Y., 'An Experimental Study on the Lap Strength of Headed Steel Reinforcements with Lap-spliced', Journal of Aik, Vol. 24, No. 3, pp 87-94, 2008. 38.Rajagopal, S., Prabavathy, S., 'Seismic behavior of exterior beam-column joint using mechanical anchorage under reversal loading: an experimental study', IJST, Transactions of Civil Engineering, Vol. 38, No. C2, pp 345-358, 2014. 39.Kang, T.H.K., Ha, S.S., Choi, D.U., 'Bar pullout tests and seismic tests of small-Headed bars in beam-column joints', ACI Structural Journal, Vol. 107, No. 1, pp. 32-42, 2010. 40.Kang, T.H.K., Mitra, N., 'Prediction of performance of exterior beam-column connections with headed bars subject to load reversal', Engineering Structural, Vol. 41, pp. 209-217, 2012. 41.王敬仁,「新型螺紋節鋼筋續接器之研究」,國立成功大學機械工程學系碩士論文,民國95年7月。 42.吳長明技師,淺談鋼筋續接器,臺灣省土木技師公會,2005/05/07。 43.「結構混凝土設計規範與解說」,內政部營建署(2002)。 44.邱政麟,「新型螺紋節鋼筋續接器之設計」,國立成功大學機械工程學系碩士論文,民國94年6月。
摘要: 鋼筋無法依照工程的需求一體成形,故需要續接器進行續接工程,而傳統鋼筋搭接處之空間常會過於狹小,在進行施工時會造成不便且品質控制較不易,高樓層建築物施工時常使用鋼筋續接器(Coupler)來取代傳統搭接法。 本研究先針對摩擦焊接型之鋼筋續接器進行力學性質品質分析與討論。進而以實務個案為例,進行實際量產作業製程之鋼筋續接器組接,藉由大量之試驗資料經統計分析後,評估摩擦焊接型之鋼筋續接器之品質管理,以提供往後摩擦焊接型鋼筋續接器製作時之參考。 研究結果顯示,摩擦焊接續接器對母材鋼筋的力學性質影響不大。但就鋼筋續接之品質變異性分析可知,鋼筋續接器隨著鋼筋號數的增大其試驗值變異性有增加趨勢,尤其以#11號鋼筋試驗值變異性增加趨勢為最大,在往後使用#11號鋼筋摩擦焊接續接器時,須特別注意其續接製作過程及驗證其續接後的品質。
Reinforcing bar cannot stay integrally formed in accordance with the need of projects, and the space often left too small for traditional reinforcing bar connection. It makes the construction inconvenient and difficult with quality controlling. Therefore, the reinforcing bar coupler is often used to replace the traditional lap splicing method in construction of high-rise buildings. The study discusses the mechanical properties of the reinforcing bar coupler with friction welding, then progresses the actual production of the coupler assembly according to the practical cases. After statistical analysis data, do the evaluation of quality management of the reinforcing bar coupler with friction welding; and provide the reference to future friction reinforcing bar coupler production. The results show that the reinforcing bar coupler with friction welding hardly affect the mechanical properties of the reinforcing bar. However, with the improvement of the quality variability of the coupler, increase the trend of the number of reinforcing bar, especially in the #11 reinforcing bar, presents the largest variability in the test data. In the future, when uses the #11 reinforcing bar to make coupler, it's necessary to pay more attention to its production process and verify its quality.
URI: http://hdl.handle.net/11455/96123
文章公開時間: 10000-01-01