Please use this identifier to cite or link to this item: http://hdl.handle.net/11455/34937
DC FieldValueLanguage
dc.contributor.authorYang, J.S.en_US
dc.contributor.author楊吉斯zh_TW
dc.contributor.authorChen, P.Y.en_US
dc.date2002zh_TW
dc.date.accessioned2014-06-06T07:48:34Z-
dc.date.available2014-06-06T07:48:34Z-
dc.identifier.issn0910-6340zh_TW
dc.identifier.urihttp://hdl.handle.net/11455/34937-
dc.description.abstractIn this study, an infrared (IR) hollow waveguide sampler was developed to detect organic compounds in aqueous samples with sample volumes less than 50 muL. This sampler was prepared by coating a thin hydrophobic film inside the IR hollow waveguide. After injecting a certain amount of aqueous solution, organic compounds could be absorbed into the hydrophobic film by partitions. By removing the residual water in the hollow waveguide sampler with a nitrogen purging gas, the absorbed organic compounds could be sensed using IR radiation. To investigate the applicability of this hollow waveguide sampler in the detection of small amounts of aqueous samples, an analytical working function was developed following an examination of the parameters which influence the analytical signals. Such factors as the volume of the aqueous solution, the sample concentration, the length of the hollow waveguide, and the sensitivity of this method were investigated. Excellent agreement between the analytical and theoretical predicted values was observed. Upon examining the linear relationship between the analyte signals and the concentration, the regression coefficients were generally higher than 0.998 in the examined concentration range of 1 to 100 ppm. Under the condition that the sample volume was 300 muL and based on three-times the spectra noise level, the calculated detection limits for this method were found at around 1 ppm for the examined analytes.en_US
dc.language.isoen_USzh_TW
dc.relationAnalytical Sciencesen_US
dc.relation.ispartofseriesAnalytical Sciences, Volume 18, Issue 5, Page(s) 555-560.en_US
dc.relation.urihttp://dx.doi.org/10.2116/analsci.18.555en_US
dc.subjectir chemical sensoren_US
dc.subjectchlorinated aromatic-aminesen_US
dc.subjecttunable diode-lasersen_US
dc.subjectwave-guide sampleren_US
dc.subjectspectroscopic methoden_US
dc.subjectfiberen_US
dc.subjectwateren_US
dc.subjecthydrocarbonsen_US
dc.subjectpolystyreneen_US
dc.subjectsoilsen_US
dc.titleDevelopment of an infrared hollow waveguide sampler for the detection of organic compounds in aqueous solutions with limited sample volumesen_US
dc.typeJournal Articlezh_TW
dc.identifier.doi10.2116/analsci.18.555zh_TW
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeJournal Article-