標題: An experimental study on a generalized Maxwell model for nonlinear viscoelastic dampers used in seismic isolation
作者: Lu, L.Y.
Lin, G.L.
Shih, M.H.
關鍵字: Maxwell model;Fluid damper;Viscoelastic damper;Sliding isolator;Seismic isolation;Energy dissipation;Shaking table test;energy-dissipation systems;viscous dampers;fluid dampers;design;performance;retrofit;motions;buildings;stiffness;frames
Project: Engineering Structures
期刊/報告no:: Engineering Structures, Volume 34, Page(s) 111-123.
摘要: 
Long-stroke fluid dampers may be installed under seismic isolation systems to provide supplementary damping. Due to the larger vibration amplitude and velocity, highly nonlinear viscoelastic behavior may exist in a long-stroke fluid damper. In order to accurately simulate the hysteretic behavior of such a damper, this paper presents and experimentally verifies a mathematical model called the generalized Maxwell model (GMM). Similar to the classic Maxwell model, the GMM is composed of a stiffness and a viscous elements connected in series. However, nonlinearity is incorporated into both elements of the GMM by assuming that their resistant forces are exponential functions of the relative velocity and deformation of the damper. By adjusting the two exponential coefficients, the GMM is able to simulate the more complicated viscoelastic behavior of fluid dampers. The GMM is reduced to the Maxwell model when both exponential coefficients are set to one. To verify the GMM, both an element test with harmonic excitations and a shaking table test with seismic excitations were conducted for a long-stroke fluid damper with highly nonlinear viscoelastic behavior. The result of the element test confirms that the GMM model is very accurate in simulating the hysteretic property of the fluid damper under a wide range of excitation frequencies, while the classic Maxwell and the viscous models may only be accurate under a certain excitation frequency. Moreover, the shaking table test, in which the fluid damper is used to provide supplementary damping for a sliding isolation system, demonstrates that the GMM is able to more accurately predict the amount of energy dissipation by the damper and also the peak isolator drift of the isolation system, especially for an earthquake with a long-period pulse. (C) 2011 Published by Elsevier Ltd.
URI: http://hdl.handle.net/11455/68768
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2011.09.012
Appears in Collections:期刊論文

Show full item record
 

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.