Please use this identifier to cite or link to this item: http://hdl.handle.net/11455/71348
DC FieldValueLanguage
dc.contributor.authorHuang, Y.L.en_US
dc.contributor.authorChen, H.J.en_US
dc.contributor.authorRosowsky, D.V.en_US
dc.contributor.authorKao, Y.G.en_US
dc.date2000zh_TW
dc.date.accessioned2014-06-11T06:01:15Z-
dc.date.available2014-06-11T06:01:15Z-
dc.identifier.issn1225-4568zh_TW
dc.identifier.urihttp://hdl.handle.net/11455/71348-
dc.description.abstractThis paper proposes a simple numerical model for use in a finite analysis (FEA) of scaffold-shoring systems. The structural model consists of a single set of multiple-story scaffolds with constraints in the out-of-plane direction at every connection joint between stories. Although this model has only two dimensions (termed the 2-D model), it is derived from the analysis of a complete scaffold-shoring system and represents the structural behavior of a complete three-dimensional system. Experimental testing of scaffolds up to three stories in height conducted in the laboratory, along with an outdoor test of a five-story scaffold system, were used to validate the 2-D model. Both failure modes and critical loads were compared. In the comparison of failure modes, the computational results agree very well with the test results. However, in the comparison of critical loads, computational results were consistently somewhat greater than test results. The decreasing trends of critical loads with number of stories in both the test and simulation results were similar. After investigations to explain the differences between the computationally and experimentally determined critical loads, it was recommended that the 2-D model be used as the numerical model in subsequent analysis. In addition, the computational critical loads were calibrated and revised in accordance with the experimental critical loads, and the revised critical loads were then used as load-carrying capacities for scaffold-shoring systems for any number of stories. Finally, a simple procedure is suggested for determining load-carrying capacities of scaffold-shoring systems of heights other than those considered in this study.en_US
dc.language.isoen_USzh_TW
dc.relationStructural Engineering and Mechanicsen_US
dc.relation.ispartofseriesStructural Engineering and Mechanics, Volume 10, Issue 1, Page(s) 53-66.en_US
dc.subjectscaffoldsen_US
dc.subjectshoresen_US
dc.subjectscaffold-shoring systemsen_US
dc.subjectload-carrying capacitiesen_US
dc.subjectfinite element analysisen_US
dc.subjectfailure modesen_US
dc.subjectstructural analysisen_US
dc.subjectconstructionen_US
dc.titleLoad-carrying capacities and failure modes of scaffold-shoring systems, Part I: Modeling and experimentsen_US
dc.typeJournal Articlezh_TW
item.languageiso639-1en_US-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeJournal Article-
item.fulltextno fulltext-
item.grantfulltextnone-
Appears in Collections:期刊論文
Show simple item record
 

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.