Please use this identifier to cite or link to this item: http://hdl.handle.net/11455/72286
標題: 扭轉耦合建築結構裝設被動調諧質量阻尼器之最佳設計及參數研究
作者: 翁駿民
林其璋
關鍵字: 扭轉耦合結構;被動調諧質量阻尼器;地震工程
出版社: 國立中興大學工學院;Airiti Press Inc.
Project: 興大工程學刊, Volume 10, Issue 3, Page(s) 25-36.
摘要: 
This paper deals with the optimal design of passive tuned mass dampers
(PTMDs) to reduce the dynamic responses of torsionally-coupled buildings under
bi-lateral earthquake excitations. Some practical design issues such as the
optimal installed locations and moving direction of PTMDs are considered. The
optimal PTMD's system parameters are determined by minimizing the meansquare
displacement response ratio of the controlled DOF between the building with and
without PTMDs. In addition, the parametric studies about the PTMD's planar
position and effect of detuning are investigated to realize their influence on
the response control efficacy. In order to reduce the structural responses when
a building subjected to bi-lateral earthquakes, the necessity of a second PTMD
and its optimum design are also studied. Performance of the proposed optimal
PTMDs is demonstrated by numerical studies of the seismic behavior of an
one-story square torsionally-coupled building with different static
eccentricities.

本文探討扭轉耦合樓房結構受水平雙向地震力作用下,被動調諧質量阻尼器
( PTMD )之最佳設計。以扭轉耦合樓房結構裝設 PTMD 前後自由度均方位移極小化的方式
計算 PTMD 的系統設計參數並討論 PTMD 之運動方向、最佳裝設樓層以及平面位置。研究結
果發現:可由結構的振態決定 PTMD 的運動方向及最佳裝設樓層與平面位置, 並分析 PTMD
的擺設平面位置及因其設計參數偏差所造成的非調諧效應對降低結構反應的影響。為有效降
低受不同方向地震所產生的結構各自由度反應,本文亦針對不同耦合程度的樓房結構探討其
所需之 PTMD 個數。最後,以不同耦合程度之單層近似對稱型扭轉耦合樓房結構受雙向地震
作用下之數值模擬驗證最佳設計之 PTMD 確實能有效降低樓房結構整體的動態反應。