Please use this identifier to cite or link to this item: http://hdl.handle.net/11455/75746
標題: 稻穀預冷作業之研究
作者: 盛中德
周子豪
關鍵字: 稻殼;預冷;能源效益
出版社: 臺中巿: 國立中興大學農學院
Project: 農林學報, Volume 47, Issue 4, Page(s) 1-12.
摘要: 
The experiment was conducted to test paddy precooling process in
three round bins. The purpose of this study is to evaluate the performance and
energy efficiency of the paddy precooling system. The inlet air temperature
was 12-14℃, relative humidit

本研究以三個筒倉進行稻穀的預冷測試,以評估其預冷作業時之作業性能、能
源效益。系統在入筒倉之溫度12.14℃、相對濕度90.92%、稻穀含水率15%,在三筒倉滿
倉時(共33噸),得其作業之能源效益約為45.3%,在試驗時間1000min結束後,筒倉內的
溫差為1.4-2.4℃、其所引發的空氣自然對流稻穀水分轉移的效果非常有限。